Page 25 - DT Vol 13 No 2
P. 25

22-26-Show Yamamoto-Q8_6-7-8-Ivoclar.qxd  6/20/2023  1:12 PM  Page 4






             DENTAL TECHNOLOGY, APRIL-JUNE 2023
                                                                                         cosmetic section  25


















               3
              I
                                                        G


              G
                                                          2
                                                         3


                                                          :

                                                                                                 G
                                                                                                  3
                                                                                                    :
                                                                                                   3
                                                                                                 I

             F FIG 31: In a second step, EE3 was added and EE4, EE5, EE8 and  F FIG 32: The result of the second glaze layering after firing  F FIG 33: After coarse finishing and polishing, the crown was
                :
                1
                                                       I
             EE9 to create a layer of enamel                                                    ready for the first in situ test


                4

                 :
                                                                       5
                                                                        :

                                                                       3
                                                                     I
                                                                      G

              I
               3

              G
             F FIG 34: The result of the bisque bake looked very natural firing on the master model  F FIG 35: The crown was inserted, and its shade was checked with Vita Linear guide 3D Master







                                                                      G
                                                                     I
              I
                                                                       7
                                                                        :

             F FIG 36: A pickup impression was taken of this clinical stage  F FIG 37: A master model was made to evaluate the accuracy and shade

                                                                       3
              G
                 :

                6
               3










                                                                                :
                                                                               9
              G
                                                                              G

                                                                               3
                                                                             I
             F FIG 38: After minimal cut back, the dental core and enamel were optimized  F FIG 39: In order to finalize the morphology, the bands of the two incisors were determined
                 :

              I
                8

               3
                                                                            and marked
             FINALIZATION AND FINAL RESULT                                  (dark purple) and Window with EE7 (translucent orange) (Figure
             The final visual shade check was performed with Vita Linearguide  38) To be able to mimic the morphology of the adjacent incisor, the
             3D Master after replacement of the temporary crown with the new  side  and  central  bands  were  marked  with  black  and  red  pencils
             crown (Figures 34 and 35). A pick-up impression was taken to   (Figures 39 to 41). The final shape and texture were reproduced
             harmonize  the  shape  of  the  crown  with  the  structure  soft  tissues  with diamond and tungsten burs (Figures 42 to 44).
             (Figure 36). The temporary crown was recemented one last time    After fine finishing and polishing, a gold marker was applied to
             while the final crown was finalized in the laboratory by the dental  visually check the texture (Figure 45).
             technician.                                                      The crown looked very natural on the model and was therefore
               A  master  model  for  controlling  accuracy  and  shade  was  made  ready to be cemented in situ (Figures 46, 47). After inserting and
             with Vita Simulate light-curing material (for simulation of the shade  removing the excess cement, the clinical result showed a restoration
             of the 21 root) (Figure 37). A minimal cut back of the dentin core  that was natural and individual in appearance and was harmonious-
             was  optimized  with  dentin  5M3  base,  the  incisal  third  with  E05  ly placed into the esthetic area (Figures 48 and 49).
   20   21   22   23   24   25   26   27   28   29   30