10-12-Domenico Benagiano_6-7-8-Ivoclar.qxd  4/15/2024  7:57 AM  Page 2







              DENTAL TECHNOLOGY, JANUARY-MARCH 2024
                                                                                  implantology section  11
































              FIG 3                                                          FIG 4





























              FIG 5                                                          FIG 6























              FIG 7                     FIG 8                     FIG 9

              Solare also manufactured by MESA.                                The same conditions were found in the subsequent checks even 3
                The  thermal  relaxation  treatment  and  normalization  of  the  years later, at the time of writing of this article.
              chromium-cobalt alloy was carried out in a Dekema Austromat 3001  The absence of cracks or marks on the aesthetic material confirms
              laboratory furnace.                                            the  correct  interface  between  the  Magnum  Solare  alloy  and  the
                The treatment was carried out to dissipate any tension introduced  ceramic material. A bond also promoted by the heat treatment car-
              into the metal material during milling and it is used to reduce the  ried out after milling. The polishability of the Magnum Solare milled
              risk of cracks in the ceramic when firing it.                  alloy is an element that definitely contributed towards maintaining
                                                                             the health of the gingival tissues due to the poor bacterial adhesion
              RESULTS                                                        observed on this surface.
              When  delivering  the  finished  work,  there  was  observed  optimal
              structure/ fixtures fit and full passivity during the Sheffield test. 6  LIMITS
              months later, there was observed the absence of gingival retraction,  The  financial  investment  by  all  professional  parties  involved  is
              health of the periodontal tissues and optimal cleanliness level of the  objectively high, and this could hinder transition from analogue to
              prosthesis product.                                            digital. Furthermore, beware not to underestimate the investment in